CUPED in Python: Reduce A/B Test Variance with a Pre-Experiment Covariate

Implement CUPED in Python: adjust an A/B test metric with pre-experiment data to shrink confidence intervals, check it against OLS, and see how much variance you can remove.

CUPED (Controlled-experiment Using Pre-Experiment Data) shrinks the noise in an A/B test by subtracting the part of each user's metric that their pre-experiment behavior already predicts. In Python it's three lines: theta = np.cov(y, x)[0, 1] / np.var(x, ddof=1), then y_cuped = y - theta * (x - x.mean()), then run your usual t-test on y_cuped. The estimate of the treatment effect stays the same on average, but its confidence interval gets narrower, so you reach a decision with fewer users or less time.

Quick Example

The data is simulated: weekly minutes watched for 8,000 users, split evenly into control and treatment, with a true treatment effect of +3 minutes. pre is each user's viewing in the four weeks before the test and post is viewing during it.

import numpy as np
import pandas as pd
from scipy import stats

rng = np.random.default_rng(5)
n = 4000
user_level = rng.gamma(4, 30, 2 * n)                        # stable viewing habit
pre = (user_level + rng.normal(0, 25, 2 * n)).clip(0)        # before the test
group = np.repeat([0, 1], n)                                 # 0 = control, 1 = treatment
post = (user_level + rng.normal(0, 25, 2 * n) + 3.0 * group).clip(0)  # during: +3 min effect
df = pd.DataFrame({"group": group, "pre": pre, "post": post})

# CUPED: remove the part of `post` that `pre` predicts
theta = np.cov(df["post"], df["pre"])[0, 1] / df["pre"].var()
df["post_cuped"] = df["post"] - theta * (df["pre"] - df["pre"].mean())

for col in ["post", "post_cuped"]:
    a, b = df.loc[df["group"] == 1, col], df.loc[df["group"] == 0, col]
    res = stats.ttest_ind(a, b, equal_var=False)
    ci = res.confidence_interval(0.95)
    print(f"{col:11s} lift = {a.mean() - b.mean():+.2f}  "
          f"CI [{ci.low:.2f}, {ci.high:.2f}]  p = {res.pvalue:.2g}")
post        lift = +1.16  CI [-1.67, 3.98]  p = 0.42
post_cuped  lift = +3.47  CI [2.02, 4.92]  p = 2.7e-06

On this run the raw comparison is inconclusive (the interval runs from -1.67 to +3.98 minutes), while the CUPED-adjusted one clearly detects a positive effect. The CUPED interval is 2.9 minutes wide against 5.7, about half the width. The raw estimate of +1.16 landed below the true +3 purely by chance. That's the problem CUPED addresses: users differ a lot in baseline viewing, and that variation buries the treatment effect.

Two dot and whisker confidence intervals for the estimated lift in minutes: the raw interval is wide and crosses zero, the CUPED interval is about half as wide and sits entirely above zero

Why CUPED Works

Most of the variation in post has nothing to do with the treatment. Heavy viewers watch a lot in any week, and light viewers watch little. In this data the pre-period and test-period minutes have a correlation of r = 0.86:

Scatter plot of minutes watched before the test versus minutes watched during it, showing a tight upward linear relationship with a fitted line of slope 0.85

The fitted line's slope is theta (0.85). CUPED subtracts theta * (pre - mean(pre)) from each user's post. Because pre was measured before the experiment, it can't be affected by treatment, so the adjustment doesn't bias the comparison between arms. It only removes baseline differences between users. Centering pre at its mean keeps the adjusted metric on the original scale.

How much variance you remove depends on the correlation: the adjusted variance is (1 - r²) times the original.

Line chart of the share of variance remaining after CUPED against the correlation between covariate and metric, falling from 100 percent at r of 0 toward 0 at r of 1, with this test marked at r of 0.86 and 26 percent remaining

At r = 0.86, 26% of the variance remains, and the code confirms it: df["post_cuped"].var() / df["post"].var() is 0.263. Confidence interval width scales with the standard deviation, so the width drops to sqrt(0.263), or 51% of the original. The picture for weaker covariates is much less dramatic. At r = 0.3 you keep 91% of the variance, and at r = 0.5, 75%.

Does CUPED Give the Same Answer as Regression?

Yes, nearly. CUPED is equivalent to regressing the metric on the treatment flag plus the pre-experiment covariate (ANCOVA). With statsmodels:

import statsmodels.formula.api as smf

ols = smf.ols("post ~ group + pre", df).fit()
ols.params["group"], ols.conf_int().loc["group"].tolist()
# (3.474, [2.025, 4.923])

The coefficient on group is 3.474 against CUPED's 3.473, with an interval of [2.03, 4.92] against [2.02, 4.92]. The regression is handy when you want to add several covariates at once, such as pre-period spend and tenure, or when you want robust standard errors with .fit(cov_type="HC3"). CUPED's single-covariate form is easy to explain and to run in a data warehouse or a dashboard.

How Often Does CUPED Detect a Real Effect?

One simulation can flatter either method, so this repeats the experiment 500 times with the same +3 minute effect, a fresh sample each time, and counts how often each analysis reaches p < 0.05:

Analysis Share of runs that detect the effect
Raw metric 52.6%
CUPED-adjusted 98.4%

CUPED turns a coin-flip test into a reliable one on identical data. The practical use is the other direction too: for a fixed power target you need fewer users, roughly (1 - r²) times as many.

Rules for Choosing the Covariate

  • Measure it before the experiment starts. Anything collected after assignment can be influenced by the treatment, and adjusting for it biases the estimate.
  • Use the same metric from a prior period when you can. Pre-period minutes predict test-period minutes better than almost anything else. A different but correlated metric (such as pre-period sessions) works, with a lower r.
  • Fit theta on both arms pooled. That's what the example does. Estimating it separately per arm adds noise and complexity.
  • Handle users with no history. New users have no pre-period data. Fill with the mean (their adjustment is then zero) or fit CUPED only where the covariate exists, and say so when reporting.
  • Don't expect miracles for new products. With r near zero there's nothing to remove, and CUPED returns about the same interval as the raw test.

When to Use CUPED

Situation Use CUPED?
Metric is stable per user (time spent, spend, sessions) Yes, r is usually 0.5 to 0.9
Binary conversion where most users are new Little gain, r is small
Long-running test, covariate from the same period No, the covariate must predate assignment
Several useful pre-period features Use the regression form with several covariates

Similar Topics