A Bland-Altman plot checks whether two measurement methods agree. Plot the
difference between each pair of readings against their average, then add
lines at the mean difference and at mean ± 1.96 standard deviations (the limits
of agreement). In Python, draw it with Matplotlib or call
statsmodels.api.graphics.mean_diff_plot(). This post uses Matplotlib 3.11 and
statsmodels 0.15.
Quick Example
A wrist heart rate sensor compared with a chest strap on 120 people:
import matplotlib.pyplot as plt
import numpy as np
rng = np.random.default_rng(211)
true_rate = rng.uniform(55, 165, 120)
chest = true_rate + rng.normal(0, 1.5, 120)
wrist = true_rate + 2.0 + rng.normal(0, 4.0, 120)
mean = (wrist + chest) / 2
diff = wrist - chest
bias = diff.mean()
sd = diff.std(ddof=1)
low, high = bias - 1.96 * sd, bias + 1.96 * sd
fig, ax = plt.subplots(figsize=(8.5, 4.8))
ax.scatter(mean, diff, s=22, color="#5e548e", alpha=0.75)
for value, label, style in [(bias, "Bias", "-"),
(high, "Upper limit", "--"),
(low, "Lower limit", "--")]:
ax.axhline(value, color="#bc4749", ls=style, lw=1.5)
ax.text(1.01, value, f"{label}\n{value:+.1f}", va="center",
transform=ax.get_yaxis_transform(), fontsize=9)
ax.set_xlabel("Average of the two readings (bpm)")
ax.set_ylabel("Wrist minus chest (bpm)")
plt.show()
print(f"bias {bias:.2f}, limits of agreement {low:.1f} to {high:.1f}")
bias 2.76, limits of agreement -5.0 to 10.5

How do I read a Bland-Altman plot?
- Bias (middle line): how much higher one method reads on average. Here the wrist sensor reads about 2.8 bpm high. The simulation built in 2, and the rest is sampling noise.
- Limits of agreement: about 95% of differences should fall between them, if the differences are roughly normal.
- Pattern: the points should form a level band. A slope or a funnel means agreement depends on the size of the measurement.
Whether the limits are acceptable is not a statistical question. Decide how large a difference matters before looking, then check that both limits are inside it.
Why not just use correlation?
Correlation measures whether two things move together, not whether they give the same number. A sensor that always reads 20 bpm high has the same correlation as an accurate one.
shifted = wrist + 20
print(f"r = {np.corrcoef(chest, wrist)[0, 1]:.3f}, "
f"mean difference {np.mean(wrist - chest):.1f}")
print(f"r = {np.corrcoef(chest, shifted)[0, 1]:.3f}, "
f"mean difference {np.mean(shifted - chest):.1f}")
r = 0.992, mean difference 2.8
r = 0.992, mean difference 22.8
Add confidence intervals
The bias and limits are estimates from a sample. With n pairs, the standard
error of the bias is sd / sqrt(n) and of each limit is approximately
sd * sqrt(1/n + 1.96**2 / (2 * (n - 1))).
from scipy import stats
n = len(diff)
t = stats.t.ppf(0.975, n - 1)
half_bias = t * sd / np.sqrt(n)
half_limit = t * sd * np.sqrt(1 / n + 1.96**2 / (2 * (n - 1)))
fig, ax = plt.subplots(figsize=(8.5, 4.8))
ax.scatter(mean, diff, s=22, color="#5e548e", alpha=0.75)
for value, half in [(bias, half_bias), (high, half_limit), (low, half_limit)]:
ax.axhline(value, color="#bc4749", lw=1.3)
ax.axhspan(value - half, value + half, color="#bc4749", alpha=0.15)
ax.set_xlabel("Average of the two readings (bpm)")
ax.set_ylabel("Wrist minus chest (bpm)")
plt.show()
print(f"bias {bias - half_bias:.1f} to {bias + half_bias:.1f}")
print(f"upper {high - half_limit:.1f} to {high + half_limit:.1f}")
print(f"lower {low - half_limit:.1f} to {low + half_limit:.1f}")
bias 2.1 to 3.5
upper 9.3 to 11.7
lower -6.2 to -3.8

Use statsmodels mean_diff_plot
import statsmodels.api as sm
fig, ax = plt.subplots(figsize=(8.5, 4.8))
sm.graphics.mean_diff_plot(wrist, chest, ax=ax,
scatter_kwds={"color": "#386641", "s": 22})
plt.show()

It plots the first argument minus the second. Change the limit width with
sd_limit. Its standard deviation uses ddof=0, so the limits are very
slightly narrower than the ones above.
What if the spread grows with the measurement?
Many instruments have error proportional to the value, which makes a funnel. Analyze the differences of the logs, then convert back to ratios.
actual = np.exp(rng.uniform(np.log(5), np.log(200), 150))
lab = actual * np.exp(rng.normal(0, 0.04, 150))
handheld = actual * 1.06 * np.exp(rng.normal(0, 0.09, 150))
fig, axes = plt.subplots(1, 2, figsize=(10, 4.2))
avg = (lab + handheld) / 2
for ax, d, title in [
(axes[0], handheld - lab, "Raw difference: funnel shape"),
(axes[1], np.log(handheld / lab), "Log ratio: level band")]:
m, s = d.mean(), d.std(ddof=1)
ax.scatter(avg, d, s=16, color="#bc6c25", alpha=0.75)
for v, style in [(m, "-"), (m + 1.96 * s, "--"), (m - 1.96 * s, "--")]:
ax.axhline(v, color="#283618", ls=style)
ax.set_title(title)
ax.set_xlabel("Average reading")
axes[0].set_ylabel("Handheld minus lab")
axes[1].set_ylabel("ln(handheld / lab)")
fig.tight_layout()
plt.show()
logs = np.log(handheld / lab)
ratios = np.exp([logs.mean(), logs.mean() - 1.96 * logs.std(ddof=1),
logs.mean() + 1.96 * logs.std(ddof=1)])
print("ratio: bias {:.2f}, limits {:.2f} to {:.2f}".format(*ratios))
ratio: bias 1.07, limits 0.88 to 1.29

The handheld reads about 7% higher than the lab on average, and about 95% of its readings should fall between 12% below and 29% above the lab value.
Practical tips
- Put the average on the x-axis, not one method's reading, unless that method is a true reference with negligible error.
- Repeated measurements from the same person aren't independent. The formulas here assume one pair per subject.
- Check the differences for normality with a Q-Q plot.
- Report the sample size, bias, limits and their intervals together.